Baumfolder Baumcut Programmable 26.4 Uživatelský manuál Strana 43

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 42
K5A - 9
Program data display:
5.0 Automatic Operation
after 1. input: input section shows 30.735
after 2. input: backgauge moves
after backgauge stops: measurement display shows 30.735
Conditions: Automatic OFF
A Measurement input with metric system (cm)
Example:
Size Key input
1. 30,735
2. Positioning, press 2 x shortly
________________________________________________________________
B Measurement input in inches
Same way of input as for metric system
however
value in inches entered as a fraction:
Example:
Size Key input
1. 12 1/2"
2. Positioning, press 2 x shortly
Note:
For whole sizes (no digits behind decimal point) zeroes do not have to be
keyed in. This is done automatically.
Automatic Backgauge Adjustment through Numerical Keyboard
Zobrazit stránku 42